AIDEKE / SYSTEM STUDY 16+Variable-demand nitrogen supply — manufacturer equipment reference photoManufacturer reference photo · sjjq.com

01Define the operating duty

A peak may last minutes while demand stays low through most of a shift. Measure production, changeovers, breaks and overnight use separately. Temporary metering can establish a baseline where reliable records are unavailable.

  • Demand input: Complete shift demand curve

02Connect the complete system

Compare modulation, staged starts and buffering together with compressor control. Reduced nitrogen consumption does not guarantee proportional compressor savings. Record gas and electricity over matching periods to assess the response of the whole station.

  • Interface input: Minimum sustained load; Peak duration

03Verify the configuration

Test low-load purity, recovery to full demand and cycling frequency. Compare energy at equal delivered quantity and quality, including all auxiliaries. Refine controls around actual shifts rather than extrapolating one design point.

This topic supports configuration discussions. Equipment combinations and availability are subject to technical confirmation and contract. The fields below are project inputs, not committed performance specifications.

  • Verification input: Whole-station metering boundary

Selection conditions to confirm

ItemRequirement / confirmation basis
Complete shift demand curveConfirm for the projectProvide actual process conditions and the measurement basis.
Minimum sustained loadConfirm for the projectSpecify normal values, peaks or the permitted range.
Peak durationConfirm for the projectCheck against existing equipment and site conditions.
Whole-station metering boundaryConfirm for the projectAgree the acceptance basis during technical review.