01Read the reference conditions
Normal or standard volume labels are used with different conventions. State the reference temperature and absolute pressure explicitly rather than assuming every supplier uses the same definition. Clarify whether the volume is dry or includes water vapour.
02Distinguish line volume
Actual cubic metres per hour describe volume at the gas's operating conditions. That value can differ substantially from a normalized flow for the same gas quantity. Pressure stated as gauge pressure also needs conversion to the appropriate absolute basis for calculations.
03Normalize before comparing
Check compressor data, generator ratings, flow-meter settings and purchased-gas records on one agreed basis. Preserve the original values and conversion assumptions. A numerical mismatch caused by different reference conditions should be resolved before it is treated as a capacity shortfall.
These public references explain general technology. They do not establish AIDEKE model performance, a supply commitment or a third-party endorsement. The article is an independent editorial explanation; the confirmed technical agreement governs a specific project.