01Define the station boundary
List the included compressors, dryers, separators, cooling auxiliaries and boosters. If one proposal excludes a major consumer, its specific-energy figure cannot be compared directly with a complete-station figure. State whether standby and regeneration consumption are included.
02Count accepted delivered gas
Use gas delivered at the agreed quality and pressure, on a stated volume-reference basis. Rejected startup gas, analyser sampling and leaks may affect the relationship between generated and useful output. Align the electricity and flow measurement periods.
03Compare representative duty
Evaluate a realistic load profile, including low-demand hours, rather than only a rated point. Keep inlet conditions and quality targets with the result. An energy figure without these conditions is a useful question for the supplier, not sufficient evidence for a savings commitment.
These public references explain general technology. They do not establish AIDEKE model performance, a supply commitment or a third-party endorsement. The article is an independent editorial explanation; the confirmed technical agreement governs a specific project.